The XC-9000 system is a completely digital network PA system based upon the TCP/IP procedure. By leveraging the TCP/IP protocol, the system makes sure the appropriate and effective transmission of all information packages. Not just can it use existing computer system networks, such as LANs or the Internet, to transmit broadcast signals, yet also it can likewise be deployed on a dedicated broadcasting network.


A single-server system can support up to 3000 terminals and allows for web server plunging. There are no constraints on the simultaneous broadcast channels, achieving real complete digital broadcasting.


System Characteristics



Adaptable PA System Style


The PA system architecture is simple, including service administration software application, network microphones, network amplifiers, network speakers, and other devices.All tools is linked by means of the TCP/IP intranet procedure, allowing for flexible arrangement and very easy monitoring of the system, with free control over program material, network tools, and regions through the network.


Ip Pa SystemIp Paging System
Comprehensive Audio Management


The audio monitoring software application consists of integrated attributes for developing broadcast strategies, versatile zoning, and pre-scheduled broadcasts.It sustains 24-hour programs, enabling for transforming setups during all the time


Versatile Audio Resource Support


The system sustains various kinds of audio sources for sending out alerts like live speech and BGM playback. Audio resources can originate from digital musical applications, CD/DVD players, microphones, and so on. Furthermore, the system provides diverse functions of sustaining various broadcasting attributes such as arranged broadcasting, zoned broadcasting, and emergency broadcasting.


Fire Alarm System Integration


The system has a fire alarm feature and can be integrated right into a fire alarm system. When the alarm system main system obtains the alarming signals, the cord will transfer the signal to gadgets, which triggers the XC-9000, sending signals to speakers


Customers could choose to pre-programmed settings to turn on full-area or zoned alarms in emergencies. The alarm voices come in several types and might be modified dealing with demands. Individuals can alter language setups, upload and modify their audio sources according to specific needs, such as intruding alarm systems, fire alarm systems or air help alarms, and so on.


Emergency Alarm System Combination


The system has an emergency alarm feature and can be integrated right into a smoke alarm system. When the alarm system main device obtains the startling signals, the cable television will certainly transfer the signal to gadgets, which activates the XC-9000, sending out signals to speakers


Individuals might select to preset setups to turn on full-area or zoned alarms in emergencies. The alarm voices come in numerous forms and could be modified providing to demands. Customers can alter language settings, upload and edit their audio resources according to specific requirements, such as intruding alarms, fire alarm systems or air help alarms, etc.


App Control for System Workflow


The system makes it possible for mobile application login and usage, allowing users to initiate programs and various other operations to authorized terminals through the server software application, making certain a hassle-free and structured experience.


Integrated SIP Compatibility


The system not just permits SIP phones to log in, but also can be connected to third-party SIP web server or IPPBX, which establishes a completely integrated and suitable communication system through smooth combination into existing systems.


Open SDK


When huge job like wise park occurs, the system provides an open SDK incorporated into third-party application systems - SPON Communications


System Facilities



Main Functions


Set up Playback


The system is able to automatically transmit according to the scheduled jobs as long as customers submit the audio declare each period of the day to the web server and create a playback timetable.


Area Broadcasting


The system can randomly divide a couple of network gadgets into various areas to play specified audio programs or send out news to any type of marked area. The quantity of each tool can be from another location adjusted.


Real-time Broadcasting


The system can catch and transmit radio programs or other external audio resources in real-time, and at the very same time broadcast them in sync.


Fire Alarm System Integration


The system can be incorporated with the emergency alarm system for control. When a fire alarm system signal is caused, it immediately activates the emergency situation broadcast feature and sustains adjacent flooring alarms. It likewise permits hands-on emergency broadcasting by clicking a single button.


SIP Phone Assimilation


The system can be integrated with SIP web servers, permitting live speech of voice broadcasting by means of SIP phones to send out statements anytime and anywhere.


CCTV Assimilation


The electronic gadgets such as IP POE Speakers adopts the worldwide conventional ONVIF method, which enables their voices to be relayed via VMS systems. The terminals can also be integrated with CCTV systems for synchronized broadcast.


Main Products



Audio Management Software Program XC-9000


B/S style, sustains cross-platform applications.
Covers conventional broadcasting system works, enabling for dividing monitoring.
Unified monitoring of terminals within the system, watching work condition, and set volume adjustment, and so on.
Supports building multi-level server architectures, releasing administration according to user geographical regions.
Provides SDK development plans for second development and assimilation with various other system platforms.


Network Paging Console XC-9038N


Power: DC12V/1.5 A.
Present: 4-inch touchscreen, resolution 480 * 480.
Interaction Procedures: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Regularity Feedback: 100Hz~ 16KHz.
Operating Temperature: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.


Network Paging Console XC-9037N


Power Supply: DC12V/1.5 A.
Show: 4-inch touchscreen, resolution 480 * 480.
Interaction Procedures: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Regularity Feedback: 100Hz~ 16KHz.
Operating Temperature: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.


Network Horn Audio Speaker GEN-6391A03


Power Supply: DC24V/2.7 A or POE.
Interaction Procedure: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Frequency Action: 100Hz~ 18KHz.
Intercom: Supported, Built-in Microphone.
Running Temperature level: -20~ 50 ℃.
Measurements: 283.1 * 224.3 * 269mm.


Network Ceiling Speaker GEN-6211A03


Power Supply: DC 24V/1A or POE.
Communication Protocols: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency Action: 100Hz~ 18KHz.
Operating Temperature level: -20 to 50 ° C.
Capacities: φ213 x 165mm.


Network Wall Mount Audio Speaker GEN-6011A03


Power Supply: DC24V/1A or POE.
Communication Protocol: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency Action: 100Hz~ 18KHz.
Running Temperature level: -20~ 50 ℃.
Dimensions: 193x151.5 x292mm.


Network Column Speaker GEN-6191A03




Power Supply: DC24V/1A or POE.
Interaction Procedure: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 90dB.
Frequency Action: 45Hz~ 18KHz.
Running Temperature level: -10~ 55 ℃.
Dimensions: 296x140x130mm.


Network Sound Bridge GEN-3101A01


Power Supply: POE.
Interaction Procedure: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 85dB.
Regularity Response: 50Hz~ 20KHz.
Operating Temperature level: -10~ 55 ℃.
Measurements: 126x66x27mm.


Network Digital Amplifier XC-9508P


Power Supply: AC100V~ 240V, 50/60Hz.
Power: 130W, 260W, 360W, 500W.
Communication Method: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Regularity Response: 60Hz~ 18KHz.
Running Temperature level: -10~ 50 ℃.
Measurements: 440x300x44mm.


Zone Combining Digital Amplifier NBS-2301


Power Supply : AIR CONDITIONER 220V, 50Hz.
Power : 130W , 260W , 360W , 550W , 700W.
Communication Method : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP.
Signal-to-Noise Ratio :.
Mic Input 01: ≥ 65dB,.
Mic Input click here for more 02/03: ≥ 80dB,.
Aux Input 01/02: ≥ 82dB.
Frequency Reaction :.
Mic Input 01: 80Hz~ 14kHz.
Mic Input 02/03: 60Hz~ 16kHz.
Aux Input 01/02: 60Hz~ 16kHz.
Operating Temperature :.
10 ℃~ +50 ℃ (14 ℉~ 122 ℉)
Measurements : 483x430x88mm.


IP Interface System NAC-5003


Power Supply: AC100V~ 240V, 50/60Hz.
Interaction Protocol: TCP/IP, UDP.
Interfaces: 1 Ethernet port, 32 alarm system inputs, 8 alarm system outputs.
Operating Temperature: -10~ 50 ℃.
Measurements: 483x259x44mm.


Solution For Institution





Flexible Zoning Program:


The totally network terminals can understand adaptable zoning options, permitting transmitting notices to private terminals or different zones ( tools).


College Bell System:


It supplies college bell system at the beginning/ending of the course - IP PA System. Numerous circumstances can be created, including different scheduled broadcast jobs according to summer/winter schedule


Fire Alarm Integration


It sustains assimilation with smoke alarm systems, allowing emergency alarm signals to be incorporated right into the PA system.


Class Sound Amplification


Terminals support day-to-day applications in class scenes. They can be linked to projectors or interactive whiteboard for audio boosting.


Spon CommunicationsSpon Communications

Smart Road Lamp/Security Pole



Assistance SIP Procedure:


Integrated SIP method for smooth combination with network interaction systems.


VMS Operatings Systems Combination:


Integrated ONVIF protocol for combination with VMS platforms.


Third-Party Assimilation:


Integrated In HTTP API for assimilation with 3rd party platforms.


Voice Alarm System Activating:


Developed in alarm system input interface for causing voice alarms with electronic cameras.


Service For Hotel



Area Control by Floor:


The system supplies full network setups, splitting areas depending on various floors and control over each zone separately.


Emergency Alarm Combination:


The hop over to here system can be integrated with smoke alarm system, making it possible for combination of emergency alarm signals right into the broadcasting system.


Scheduled Broadcasting:


It sustains programmable arranged broadcasting, permitting flexible arrangements according to different demands.


Emergency Broadcasting:


It supports emergency situation broadcasting for the entire area, enabling one-click emergency situation communication.


Remedy For Factory



Area Broadcasting:


It enables relaying to any zone, assuring no disturbance between various areas.


Alarm Triggering:


Terminals have different sort of interfaces, enabling to cause alarms when attached with video cameras.


All Network Tools:


Release of fully network tools dramatically reduces the problem of running such as examining tools on hazardous websites, and thus protecting people and home.


The release of all network gadgets significantly decreases the problem of operation and maintenance management


Integrated SIP Phones:


The system can be integrated with SIP phone and broadcast notices utilizing SIP phones at any moment and anywhere. Two-way audio talkback between SIP phones and IP POE Audio speakers makes it very easy for inspecting gadgets being in office or various other workplaces.


The XC-9000 system is a fully electronic network PA system based on the TCP/IP procedure. By leveraging the TCP/IP protocol, the system ensures the right and effective transmission of all data find packets. The system sustains various forms of audio resources for sending out notices like online speech and BGM playback. In addition, the system provides diverse functions of supporting numerous broadcasting functions such as arranged broadcasting, zoned broadcasting, and emergency situation broadcasting.


The system can be integrated with the fire alarm system for control.